      Model No : DSW928N    
The product is a new type of photoelectric smoke alarm,When it detects smoke twice,it will output signal immediately and trigger connected unit to work,which tell you in advance that fire will occurs and avoid unwanted loss,and take you safety and convenience.

SPECIFICATION: Power supply: DC12V-DC24V
Static current (like following diagram):

Working current: 16mA-17mA
Detecting time: detect once every about 5s
Detecting smoke method: it works only when it detects smoke twice.
PDF: size: 133KB
 
WHERE NOT TO INSTALL SMOKE ALARMS
1. Where combustion are permitted to produce. For example unventilated kitchens, garages, and furnace;
2. near fanner;
3. In very damp, humid or steamy areas: Keep units at least 3m away from showers saunas, dishwashers, etc.
4. In very dusty, dirty, or greasy areas;
5. In very drafty areas, where smoke will be blown away from the unit completely,
6. in air-logged areas, that will clog the sensing chamber;
7. Less than 305mm away from fluorescent lights. Electrical “noise” can interfere with the sensor.
8. In “dead air” space, for example, in Diagram 1, near the corner less than 10cm.
9. in smoking meeting room, don't install the alarm there for the unit will alarm when several persons smoke.

  • SMOKE ALARM FOR MINIMUM PROTECTION
  • SMOKE ALARM FOR ADDITIONAL PROTECTION
  •  
     

    WHERE TO INSTALL SMOKE ALARMS

    At first, you need install one item in every bedroom and route way at least.
    Stairway is important for you to rush out when fires occur, so there must install smoke detector on the top of stairway.
    You at least require one smoke alarm in every space of every floor, including finished attics and basements.
    Install one alarm beside every electric facility.
    You’d better Install smoke alarms in the middle of ceiling, because smoke always spread up;
    If some reasons cause you can’t install them in the middle of ceiling, you also need to install them at least 10cm away from the wall.
    If you like to install them on the wall, they should be installed 10-30.5cm away under the ceiling. Diagram 1.
    You need install more than one alarm when the length of your hall exceeds 9m.
    In an oblique roof room, install the alarm 0.9m away from the top. Diagram 2.
    How to install smoke alarms in a removable house. The removable house is short of heat isolation, so you'd better install the alarm 10-30.5cm away from the ceiling.
     
    Address: Room1621 Linqiao Piazza, Ningbo City,315010, China
    Tel: +86(574) 27861829   27861849   27861830   Fax: +86(574)87264906
    E-mail: admin@blunet.net.cn
     HTTP://WWW.BLUNET.net.cn
    Copyright ©1995-2003 DSW Electronics Ltd. All rights reserved.RSS Feeds
    ICP