            | Model No.: 
              												
              
              
              COA-2008C |  
            |  |  
            | Gas AlarmPower Source :220V AC
Sensitivity :Propane LEL 2.1 Vol% / HEL(UEL) 9.5 Vol% 
Butane LEL:1.8 Vol% / HEL(UEL)8.4 Vol% 
Methane LEL:5.0 Vol% / HEL(UEL) 15.0 Vol% 
Power Consumption :1.7W 
Operating Temperature :-10oC~50oC 
Ambient Humidity :Less than 95% RH 
Horn Level :75 Decibels |  
            |   |  | 
          
            | Model No.: 
              												
              
              
              COA-11 |  
            |  |  
            | Gas AlarmPower Source :12VDC 
Sensitivity :Propane LEL 2.1 Vol% / HEL(UEL) 9.5 Vol% 
Butane LEL:1.8 Vol% / HEL(UEL) 8.4 Vol% 
Methane LEL:5.0 Vol% / HEL(UEL)15.0 Vol% 
Power Consumption :1.7W 
Operating Temperature :-10oC ~ 50oC
Ambient Humidity :Less than 95% RH 
Horn Level :75 Decibels |  
            |   |  | 
          
            | Model No.: 
              												
              
              
              COA-88 |  
            |  |  
            | Coal Gas / Natural Gas / LPGPower Input:Household Power Supply AC 220V 50Hz Or DC 12V 
Buzzer Level:>=70dB/m
Alarm Density:15% LEL
Operating Temperature:-10oC to + 40oC
Operating Humidity:<=90% RH
Stability:<=+/-5% LEL
Repetition:<=+/-5% LEL
Alarm Density Error:<=+/-5% LEL
Alarm Mode:Flas |  
            |   |  | 
| 
          
            | Model No.: 
              												
              
              
              COA-88A |  
            |  |  
            | Coal Gas / Natural Gas Power Input:Household Power Supply AC 220V 50Hz Or DC 12V 
Buzzer Level:>=70dB/m
Alarm Density:15% LEL
Disalarm Density:8% LEL
Operating Temperature:-10oC to + 40oC
Operating Humidity:<=90% RH
Stability:<=+/-5% LEL
Repetitiveness:<=+/-5% LEL
Alarm Density Error:&l |  
            |   |  | 
          
            | Model No.: 
              												
              
              
              COA-87 |  
            |  |  
            | Coal Gas / Natural Gas Power Input:Household Power Supply AC 220V 50Hz Or DC 12V 
Buzzer Level:>=70dB/m
Alarm Density:15% LEL
Disalarm Density:8% LEL
Operating Temperature:-10oC to +40oC
Operating Humidity:<=90% RH
Stability:<=+/-5% LEL
Repetitiveness:<=+/-5% LEL
Alarm Density Error:< |  
            |   |  | 
          
            | Model No.: 
              												
              
              
              COA-860 |  
            |  |  
            | SnO2 Semi-conductive CO sensorProcessor:Microchip controller
Alarm Concentration:Alarmed within 90 minutes under concentration of 100ppm
Alarm Concentration:Alarmed within 35 minutes under concentration of 200ppm
Alarm Concentration:Alarmed within 15 minutes under concentration of 400ppm
Buzzer:Sounded when alarmed,1 |  
            |   |  | 
| 
          
            | Model No.: 
              												
              
              
              COA-2588 |  
            |  |  
            | Gas AlarmPower Source: DC 9V   DC 12/24V 
Sensitivity: Propane LEL: 2.1 Vol% / HEL(UEL): 9.5 Vol% 
Butane LEL: 1.8 Vol% / HEL(UEL): 8.4 Vol% 
Methane LEL: 5.0 Vol% / HEL(UEL): 15.0 Vol% 
Power Consumption: 1.7W 
Operating Temperature: -10oC-50oC 
Ambient Humidity: Less than 95% RH |  
            |   |  | 
          
            | Model No.: 
              												
              
              
              COA-2008 |  
            |  |  
            | LPG, natural gas, and coal gas Power supply:AC100V~AC240V
Power frequency:50/60Hz
Rated load:<4W
Alarm thickness:LPG:0.1~ 0.5%; natural gas:0.1~ 0.3%; coal gas 0.1~ 0.5%
Alarm volume:>=85dB
Working environment:-10oC~50oC relative humidity <97%RH
Storage temperature:-25oC~55oC |  
            |   |  | 
          
            | Model No.: 
              												
              
              
              HT-1106 |  
            |  |  
            | Heat Detector detecting temperature : rate of rise 
voltage:12VDC→30VDC
alarm temperature:65°C
static current:40uA~80uA
working humidity:10~90%
Installing : ceiling installation
The power current less than 30mA |  
            |   |  | 
| 
          
            | Model No.: 
              												
              
              
              COA-2008V |  
            |  |  
            | Gas Detector&AlarmPower Source :220V AC
Sensitivity:10%LEL
Power Consumption:1.7W 
Operating Temperature:-10oC ~ 50oC 
Ambient Humidity:Less than 95% RH 
Horn Level :75 Decibels at 10 feet 
Standby Mode:Green LED on 
Alarm Mode:Red LED flashes and an acoustic alarm 
Type Of Gas Sensed:Natural |  
            |   |  | 
          
            | Model No.: 
              												
              
              
              HT928 |  
            |  |  
            | Heat detector seriesDetecting temperature method:rate of rise and fixed temperature
Power supply:DC12V→DC24V
Static current:<60uA
alarm temperature:65°C
working humidity:10→90%
installing method:ceiling installation 
Double indicator.
After installing and switching on power |  
            |   |  | 
          
            | Model No.: 
              												
              
              
              COA-1588 |  
            |  |  
            | Gas AlarmPower Source:DC 9V   DC 12/24V 
Sensitivity:Propane LEL:2.1 Vol% / HEL(UEL):9.5 Vol% 
Butane LEL:1.8 Vol% / HEL(UEL):8.4 Vol% 
Methane LEL:5.0 Vol% / HEL(UEL):15.0 Vol% 
Power Consumption:1.7W 
Operating Temperature:-10°C-50°C 
Ambient Humidity:Less than 95% RH 
Horn Lev |  
            |   |  | 
|  |  |  |